YAYOI nuclear reactor of the University of Tokyo (Model-27) 
.
[6]: TKY-M27 (YAYOI Model 27)   Experimental system
Filter: Fe(150mm), Fe(150mm), Fe(200mm), Fe(160mm), Bi(50mm), Al(400mm), Pb(50mm), Fe(5mm). E(ave)=0.017 MeV, Gamma contamination (E=2.990 MeV)=42.6 % at Gy level
Materials: Human peripheral blood (whole blood irradiation): Irradiation at 150mm apart from the surface of the filter.
Date: 1992.09.18
Dose No. of Aberrations Distribution of indicated number of aberrations
(Gy) cells Tet Tri Dic Rc Ra aM F del S del Aber 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
0 115 0 0 0 0 0 0 0 0 0 0 Dics 115
D+R 115
All 115
0.0331 330 0 0 5 2 0 0 6 0 2 2 Dics 325 5
D+R 323 7
All 321 9
0.0892 263 0 0 16 0 0 2 16 0 5 5 Dics 248 14 1
D+R 248 14 1
All 242 19 2
0.1658 218 0 0 14 4 1 3 17 0 11 10 Dics 205 12 1
D+R 201 15 2
All 190 24 4
0.2485 217 0 0 31 3 2 5 32 6 18 14 Dics 188 27 2
D+R 183 32 2
All 166 41 10
0.3315 215 0 1 43 8 4 7 54 7 23 20 Dics 176 33 6
D+R 170 34 10 1
All 148 47 16 4
0.4231 219 0 1 68 10 5 9 79 10 27 20 Dics 160 52 5 1 1
D+R 148 61 8 1 1
All 130 62 22 3 1 1
.
Ref: Sasaki, M. S., Nomura, T., Ejima, Y., Utsumi, H., Endo, S., Saito, I., Itoh, T. and Hoshi, M. (2008) Experimental derivation of relative biological effectiveness of A-bomb neutrons
in Hiroshima and Nagasaki and implication for risk assessment. Radiat. Res., 170:101-117.
.
   

TKY-M27:     E=0.0169 MeV,       Fluence rate=1.823E+07 n/cm2/sec/kW,      Kerma=0.00233 rad/sec/kW,       Kerma/n=1.293E-10 rad