Carbon-K X-ray (E=0.277 keV)

Tube voltage=1.0 kV, Current=5 mA, Filter=None, Dose rate=0.1 Gy/min
Material: Cultured mouse m5S cells (G1-arrested stationary phase)


                                        Generation system
 
.
C-K
Dose No. of Aberrations Distribution of cells with indicated number of aberrations
(Gy) cells Tet Tri Dic Rc Ra aM F del S del Aberr 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
0.1 200 0 0 10 0 0 1 12 2 3 3 Dic 190 10
D+R 190 0
Del 196 3 1
All cs 186 12 2
0.2 150 0 0 20 0 0 0 25 6 13 12 Dic 132 16 2
D+R 132 16 2
Del 135 12 3
All 122 20 6 2
0.3 150 0 0 49 0 2 3 63 16 10 8 Dic 110 32 7 1
D+R 110 30 9 1
Del 131 15 3 1
All 99 31 13 7
0.4 150 0 0 75 0 7 2 90 18 20 17 Dic 96 39 10 4 1
D+R 91 42 12 4 1
Del 122 22 5 1
All 79 41 18 9 1 1 1
0.5 150 0 0 103 0 9 7 120 24 28 21 Dic 79 50 15 3 1 2
D+R 76 50 16 4 2 2
Del 113 29 8
All 59 49 25 11 2 1 2 1
.
Ref: Endo, S., Hoshi, M., Takada, J., Takatsuji, T., Ejima, Y., Saigusa, S., Tachibana, A. and Sasaki, M. S. (2006) Development, beam characterization and chromosomal effectiveness of X-rays of
RBC characteristic X-ray generator. J. Radiat. Res., 47:103-112.
.