Aluminium-K X-rays (E=1.487 keV)

Tube voltage=2.5 kV, Current=10 mA, Filter=None, Dose rate=1.8 Gy/min
Material: Cultured mouse m5S cells (G1-arrested stationary phase)


                                                                         □ Generation system
 
.
Al-K
Dose No. of Aberrations Distribution of cells with indicated number of aberrations
(Gy) cells Tet Tri Dic Rc Ra aM F del S del Aberr 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
0.1 100 0 0 5 0 1 0 8 3 3 3 Dic 95 5
D+R 94 6
Del 94 6
All cs 89 10 1
0.2 100 0 0 23 0 1 1 26 5 2 0 Dic 79 19 2
D+R 78 20 2
Del 95 5
All 75 20 5
0.3 100 0 0 55 0 5 3 70 18 18 16 Dic 61 25 12 2
D+R 58 27 12 3
Del 74 18 8
All 41 33 18 5 2 1
0.4 100 0 0 86 0 11 10 108 25 42 40 Dic 40 37 20 3
D+R 34 40 22 3 1
Del 58 22 17 3
All 21 26 28 17 3 3 2
0.5 100 0 0 133 0 5 9 157 29 36 31 Dic 20 41 25 14
D+R 19 41 23 17
Del 58 28 11 2 1
All 12 27 24 22 10 4 1
.
Ref: Endo, S., Hoshi, M., Takada, J., Takatsuji, T., Ejima, Y., Saigusa, S., Tachibana, A. and Sasaki, M. S. (2006) Development, beam characterization and chromosomal effectiveness of X-rays of
RBC characteristic X-ray generator. J. Radiat. Res., 47:103-112.
.